Returns list of all monitoring job executions¶
Description¶
Returns list of all monitoring job executions.
Usage¶
sagemaker_list_monitoring_executions(MonitoringScheduleName,
EndpointName, SortBy, SortOrder, NextToken, MaxResults,
ScheduledTimeBefore, ScheduledTimeAfter, CreationTimeBefore,
CreationTimeAfter, LastModifiedTimeBefore, LastModifiedTimeAfter,
StatusEquals, MonitoringJobDefinitionName, MonitoringTypeEquals)
Arguments¶
-
MonitoringScheduleNameName of a specific schedule to fetch jobs for.
-
EndpointNameName of a specific endpoint to fetch jobs for.
-
SortByWhether to sort the results by the
Status,CreationTime, orScheduledTimefield. The default isCreationTime. -
SortOrderWhether to sort the results in
AscendingorDescendingorder. The default isDescending. -
NextTokenThe token returned if the response is truncated. To retrieve the next set of job executions, use it in the next request.
-
MaxResultsThe maximum number of jobs to return in the response. The default value is 10.
-
ScheduledTimeBeforeFilter for jobs scheduled before a specified time.
-
ScheduledTimeAfterFilter for jobs scheduled after a specified time.
-
CreationTimeBeforeA filter that returns only jobs created before a specified time.
-
CreationTimeAfterA filter that returns only jobs created after a specified time.
-
LastModifiedTimeBeforeA filter that returns only jobs modified after a specified time.
-
LastModifiedTimeAfterA filter that returns only jobs modified before a specified time.
-
StatusEqualsA filter that retrieves only jobs with a specific status.
-
MonitoringJobDefinitionNameGets a list of the monitoring job runs of the specified monitoring job definitions.
-
MonitoringTypeEqualsA filter that returns only the monitoring job runs of the specified monitoring type.
Value¶
A list with the following syntax:
list(
MonitoringExecutionSummaries = list(
list(
MonitoringScheduleName = "string",
ScheduledTime = as.POSIXct(
"2015-01-01"
),
CreationTime = as.POSIXct(
"2015-01-01"
),
LastModifiedTime = as.POSIXct(
"2015-01-01"
),
MonitoringExecutionStatus = "Pending"|"Completed"|"CompletedWithViolations"|"InProgress"|"Failed"|"Stopping"|"Stopped",
ProcessingJobArn = "string",
EndpointName = "string",
FailureReason = "string",
MonitoringJobDefinitionName = "string",
MonitoringType = "DataQuality"|"ModelQuality"|"ModelBias"|"ModelExplainability"
)
),
NextToken = "string"
)
Request syntax¶
svc$list_monitoring_executions(
MonitoringScheduleName = "string",
EndpointName = "string",
SortBy = "CreationTime"|"ScheduledTime"|"Status",
SortOrder = "Ascending"|"Descending",
NextToken = "string",
MaxResults = 123,
ScheduledTimeBefore = as.POSIXct(
"2015-01-01"
),
ScheduledTimeAfter = as.POSIXct(
"2015-01-01"
),
CreationTimeBefore = as.POSIXct(
"2015-01-01"
),
CreationTimeAfter = as.POSIXct(
"2015-01-01"
),
LastModifiedTimeBefore = as.POSIXct(
"2015-01-01"
),
LastModifiedTimeAfter = as.POSIXct(
"2015-01-01"
),
StatusEquals = "Pending"|"Completed"|"CompletedWithViolations"|"InProgress"|"Failed"|"Stopping"|"Stopped",
MonitoringJobDefinitionName = "string",
MonitoringTypeEquals = "DataQuality"|"ModelQuality"|"ModelBias"|"ModelExplainability"
)