List Monitoring Executions
sagemaker_list_monitoring_executions | R Documentation |
Returns list of all monitoring job executions¶
Description¶
Returns list of all monitoring job executions.
Usage¶
sagemaker_list_monitoring_executions(MonitoringScheduleName,
EndpointName, SortBy, SortOrder, NextToken, MaxResults,
ScheduledTimeBefore, ScheduledTimeAfter, CreationTimeBefore,
CreationTimeAfter, LastModifiedTimeBefore, LastModifiedTimeAfter,
StatusEquals, MonitoringJobDefinitionName, MonitoringTypeEquals)
Arguments¶
MonitoringScheduleName
Name of a specific schedule to fetch jobs for.
EndpointName
Name of a specific endpoint to fetch jobs for.
SortBy
Whether to sort the results by the
Status
,CreationTime
, orScheduledTime
field. The default isCreationTime
.SortOrder
Whether to sort the results in
Ascending
orDescending
order. The default isDescending
.NextToken
The token returned if the response is truncated. To retrieve the next set of job executions, use it in the next request.
MaxResults
The maximum number of jobs to return in the response. The default value is 10.
ScheduledTimeBefore
Filter for jobs scheduled before a specified time.
ScheduledTimeAfter
Filter for jobs scheduled after a specified time.
CreationTimeBefore
A filter that returns only jobs created before a specified time.
CreationTimeAfter
A filter that returns only jobs created after a specified time.
LastModifiedTimeBefore
A filter that returns only jobs modified after a specified time.
LastModifiedTimeAfter
A filter that returns only jobs modified before a specified time.
StatusEquals
A filter that retrieves only jobs with a specific status.
MonitoringJobDefinitionName
Gets a list of the monitoring job runs of the specified monitoring job definitions.
MonitoringTypeEquals
A filter that returns only the monitoring job runs of the specified monitoring type.
Value¶
A list with the following syntax:
list(
MonitoringExecutionSummaries = list(
list(
MonitoringScheduleName = "string",
ScheduledTime = as.POSIXct(
"2015-01-01"
),
CreationTime = as.POSIXct(
"2015-01-01"
),
LastModifiedTime = as.POSIXct(
"2015-01-01"
),
MonitoringExecutionStatus = "Pending"|"Completed"|"CompletedWithViolations"|"InProgress"|"Failed"|"Stopping"|"Stopped",
ProcessingJobArn = "string",
EndpointName = "string",
FailureReason = "string",
MonitoringJobDefinitionName = "string",
MonitoringType = "DataQuality"|"ModelQuality"|"ModelBias"|"ModelExplainability"
)
),
NextToken = "string"
)
Request syntax¶
svc$list_monitoring_executions(
MonitoringScheduleName = "string",
EndpointName = "string",
SortBy = "CreationTime"|"ScheduledTime"|"Status",
SortOrder = "Ascending"|"Descending",
NextToken = "string",
MaxResults = 123,
ScheduledTimeBefore = as.POSIXct(
"2015-01-01"
),
ScheduledTimeAfter = as.POSIXct(
"2015-01-01"
),
CreationTimeBefore = as.POSIXct(
"2015-01-01"
),
CreationTimeAfter = as.POSIXct(
"2015-01-01"
),
LastModifiedTimeBefore = as.POSIXct(
"2015-01-01"
),
LastModifiedTimeAfter = as.POSIXct(
"2015-01-01"
),
StatusEquals = "Pending"|"Completed"|"CompletedWithViolations"|"InProgress"|"Failed"|"Stopping"|"Stopped",
MonitoringJobDefinitionName = "string",
MonitoringTypeEquals = "DataQuality"|"ModelQuality"|"ModelBias"|"ModelExplainability"
)